product

Power Range : 5 – 10 KVA

The HELIOS T 11S inverter model is equipped with innovative features:

  • On-line double conversion
  • 3-level battery charger to optimize battery life and efficiency
  • Input power factor: 0.99
  • Extended autonomy by using additional battery cabinets
  • Large tolerance range for input voltage in order to avoid using the batteries and preserving autonomy
  • Possibility of putting up to 4 UPS in parallel

Advantages

  • Multi-function LCD display
  • High power factor and low THDi
  • ECO function option to increase returns
  • Power generator compatible
  • Possibility of putting up to 4 ASI in parallel
  • Common or separate batteries for parallel system
  • Configurable number of batteries
  • Automatic battery test configuration
  • Multi-branch battery configuration
  • Different communication systems
  • Battery start
  • Emergency stop function

GENERAL FEATURESHELIOS T 11S - 5HELIOS T 11S - 6HELIOS T 11S - 10
Power rating (KVA/KW) 5 / 4.56 / 5.410 / 9
TechnologyOn-line double conversion
INPUT FEATURES
Voltage220/230/240Vac (1P+N)
Frequency40 à 70 Hz Auto-detection
Voltage range120-276 Vac
Power factor≥ 0.99
TDHI≤ 5 % à 100% avec charge non linéaire
ConnectionTo a terminal
OUTPUT FEATURES
Voltage220/230/240Vac (1P+N)
Frequency50 Hz (± 0,2%)
Crest factor3 :1
Voltage regulation± 2%
THDu≤ 2% avec charge linéaire ≤ 5% avec charge non linéaire
Return (in online mode)≥90%
STATIC BY-PASS
TypeAutomatic bypass
Voltage range and frequencyStandard +15% / - 45% Configurable (+5%, +10%, +25%) / (-20%, -30%)
COMMUNICATION AND DISPLAY
DisplayLCD for indicating measurements
Indicators for operational status / Lights for indicating operational status
Emergency stop switchAvailable
Communication portsRS 485 / USB
ENVIRONMENT
Operating temperature0° to 25°C
Noncondensing relative humidity0 to 95%
Sound level at 1m< 60 dB
CERTIFICATIONS
Standards and markingsCE, EN / IEC 62040-2 EN/IEC62040-1-1
OPTIONS
CommunicationCarte SNMP et Carte Contacts secs (Carte de mise en parallèle incluse)
MAINTENANCE BYPASS
TypeStandard internal maintenance by-pass (optional external by-pass)
UPS BLOCKAGE
L x H x W (in mm)655 x 250 x 590
Weight and autonomy with internal battery70 Kg / 17 mn70 kg / 13 mn85 kg / 10 mn
EXTERNAL BATTERY CABINET
Dimensions (L x H x W in mm)655 x 250 x 590
Weight and autonomy with external battery107 kg / > 60mn107 kg / 60 mn125 kg / 41 mn
Battery typeSealed lead batteries without maintenance VRLA Technology
Recharge time8-10 hours
Recharge current1 A maximum, depending on the number of branches

Autonomy: Upon consultation.

Note: Non-contractual document. The technical specifications mentioned in this document are subject to change without notice from us.